VT-HDOC Series
ALARM OUT : You can select Relay to be configure
OPERATION: You can configure output status of Relay.
DISABLE: Relay is not working
ENABLE: Relay is working once event is triggered.
MODE: You can configure activation of Relay output.
TRANSPARENT: Keep Relay output until event triggering stopped.
LATCHED: Keep relay output for duration time from the event triggered lately.
DURATION: If the alarm output mode is configured as Latched. You can configure
duration time for relay output.
TYPE : Define the transition of the signal of Alarm output
N/O (Active Low): When event triggered, the relay will go to ‘Close’ state from ‘Open’.
N/C(Active High): When event triggered, the relay will go to ‘Open’ state from ‘Close’
HDD EVENT: If you select “ON”, when HDD related Event is triggered, relay will trigger
ALARM: When sensor input, relay output will trigger.
VIDEO LOSS: When video loss occurs, replay output will trigger.
MOTION: When motion triggered, replay output will trigger.
6.5.3 BUZZER OUTPUT SETUP
.
OPERATION: You can configure the output status of Buzzer.
DISABLE: Buzzer is not working when event is triggered.
ENABLE: Buzzer is working when event triggered.
HDD EVENT: If HDD related event is triggered, Buzzer output will trigger.