Vitek VT-PTZ10 Manuale delle Istruzioni Pagina 30

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 48
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 29
VT-PTZ10
29
3.2 ALARM ( MENU => ALARM)
Highlight
ALARM in the main menu and move the joystick to the right to access ALARM
setup.
NO : Alarm input number
FUNC : Priority 1~4 calls Preset(xxx),
Priority 0 supports dedicated functions like a Pattern(Pxx), Tour(Txx),
Scan(Sxx).
PRI : Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
IN : NO/NC - normally open /Closed, OFF - ignore
OUT : R01 - Relay out 1, OFF - No output.
HLD : Alarm will be held for programmed time (01 to 99 seconds)
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms
only.
There are 5 levels of priority. 0 : Highest priority supports repeated/dedicated functions
like a Pattern(Pxx), Tour(Txx), Scan(Sxx). 1~4: Same level of alarm calls presets one
after the other.
Ex) Alarm 01 calls Pattern 01, after alarm 01 is released alarm 02, 03 will call
preset 48
and
preset 01
1. Press Menu to display the main menu on the monitor. Select the Alarm option by moving
the Joystick up/down and then move to the right to enter the detail menu.
MAIN MENU
FUNCTIONS
ALARM
SCREEN
CAMERA
SETUP
EXIT
ALARM SETUP
NO FUNC PRI IN OUT HLD LATCH
01 P01 0 OFF OFF 001 OFF
02 048 3 OFF OFF 001 OFF
03 001 1 OFF OFF 001 OFF
04 --- 3 OFF OFF 001 OFF
SAVE AND EXIT
Vedere la pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 47 48

Commenti su questo manuale

Nessun commento